Pre-assessmentRegistration Audit – Stage 2Audit Findings• A review of action taken on nonconformities identified during the previous audit• A review of the continued effectiveness of the management system in its entiretyThe continued applicability to the scope of registration
The pre-assessment audit is an optional activity, outside of the registration process, it is highly encourages that any organization to undertake to evaluate the readiness to undergo the two stage registration process. That would optimally occur prior to the stage 1 and 2 audits.
Unlike the Stage 1 and Stage 2 activities you have full discretion as to which areas the preassessment should focus on and for the length of the pre-assessment. This activity allows your organization to become familiar with the audit process and helps prepare your employees for the registration assessment.
The auditor conducting the pre-assessment will typically return to the organization for the assessment. Similar to a ‘true’ audit, the end result of the pre-assessment will be a documented report identifying findings observed during the audit and a closing meeting to discuss the issues.
The pre-assessment activity allows you to correct any issues prior to beginning the registration process.
Assessment
New requirements for certification bodies have changed the registration process. Registration is now conducted in two distinct visits- Stage One and Stage Two- each of which has defined requirements that are outlined below.
Registration Audit – Stage 1
The stage 1 audit, conducted at your facility, is primarily performed for planning and determining the readiness of an organization to undergo a stage 2 registration audit. It also facilitates communicating any needs and expectations to the organization. Activities performed at a stage 1 audit include:
• Conducting a documentation review – This review determines if the organization’s EMS documentation adequately covers all the requirements of the ISO standard
• A review of the aspects and impacts and their significance and an evaluation of the facility(s) site specific conditions
• A review of your organizations non-conformance, preventive and corrective action system • An overview of applicable regulations
• Interviewing your organization’s personnel to assess their general readiness to undertake a stage 2 audit
• Confirming the applicability of the scope of the organization’s EMS
• Obtaining evidence that internal audits and management reviews are being planned and performed
• Providing focus for the planning of the stage 2 audit
• A major non-conformity relates to the absence or total breakdown of a required process or a number of minor non-conformities listed against similar areas. A major non-conformity at the Registration Audit – Stage 2 would defer recommendation for registration until that major has been closed.
• A minor non-conformity is an observed lapse in your systems ability to meet the requirements of the standard or your internal systems, while the overall process remains in tact.
• An observation or opportunity for improvement relates to a matter about which the Auditor is concerned but which cannot be clearly stated as a non-conformity. Observations also indicate trends which may result in a future non-conformity.
Corrective Action Response
ISO 14001 Standards requires corrective action responses from all Registration Audits. Once certification is achieved, dependant upon the extent and nature of the findings, your organization may be required to submit a corrective action plan, detailing your intent to correct the non conformity.
The auditor may also recommend that your organization submit objective evidence to support the to verify closure may be required.
• Customer and interested parties communications
• Effectiveness of the management system in achieving defined objectives
• The progress of planned continual improvement activities
• Continuing operational control
• A review of any changes made by the organization which may have impact on the registration
• Use of accreditation and certification body logos provided to the organization upon registration
• objectives, targets and programs
• evaluation of compliance
Re-assessment Audits
The accreditation body requires that a recertification audit be carried out every three years. The purpose of the recertification audit is to confirm the continued conformity and effectiveness of the management system as a whole, and its continued relevance and applicability for the scope of activity.
Recertification audits review the performance of the EMS over the registration period, and include a review of previous surveillance audit records. The recertification audit includes the following:
• The continued relevancy of the organization’s policy and objectives
• The continued effective interaction between the processes of the management system
• A review of internal audits, management reviews, document changes during this certification period
nice blog ISO 14001 requirements are able to meet environment management system.
ReplyDeleteISO 14001